Battery Chargers
© Brooke Clarke 2005
Background
Battery Life
Charger Types
DC Current
DC Voltage with Current Limit
Pulse Methods
Burp Charging
Charge Termination
Self Discharge
Trickle or Float
Smart Batteries
Rechargeable Chemistries
Lead Acid
Alkaline
Ni-Cad
Ni-MH
Li-Ion
Li-Poly
Chargers
Home Made
Commercial
Military
Patents
Links
Background
This web page is a direct result of
testing many battery chargers for use with the
5590BA Battery Adapter that
uses 20 or 22 AA cells and the need for a consolidated approach.
Battery Life
A battery has some total Amp hour life. For example if the battery is
rated for 500 charge discharge cycles and 2 Ah capacity then it's total
life is 1000 Ah. This is related to both how it's charged and to how
it's discharged. If it's abused by discharging to deeply or by over
charging then the life is shortened.
The spec sheet has information on the minimum premissable discharge voltage and recomended charging methods.
The problem with charging is the battery can have it's life shortened
by over charging. Severe over charging can kill the battery just
as severe discharging can kill some batteries.
If a discharged battery is put on a charger the problem is straight forward and almost any of the charge termination (
see below) methods will work.
The problem is when a partially or fully charged battery is put on the
charger. For example if you use the C/10 for 16 hours charge on a
full battery at the end of the 16 hours the battery will not have any
more charge than it had at the start. It will be warm to hot and
it's life will have been shortened by one charge and some electricity
will have been wasted. If a full battery is put on a fast charger
that uses -dV/dt charge termination and the charger ignores -dV/dt for
the first few minutes to eliminate false stops on batteries that have
not been used for some time it may never terminate the charge. In
this case if there is no thermal limit charge termination the battery
will be killed by excessive temperature.
Charger Types
DC Current
The most common charger is just a DC current source. Most any
battery can be charged by feeding it a current that's it's specified
discharge Capacity divided by 10 (C/10). For example a Ni-MH AA
cell may be rated at 2.3 Amp Hours so it's C/10 charge current would be
230 ma. If the world was perfect you would only need to put this
current into the battery for 10 hours and you would have put in 2.3 Amp
Hours, but the battery and the charging circuit have resistance that
converts power into heat. Also the battery may generate heat as
part of the chemical reaction related to charging, like a Ni-MH that
nearing full charge which also waste power. So instead of 10
hours is common to see 12 to 16 hours for a slow charge.
For rates between C/10 and 1 C it may be possible to charge a little
faster, but it's not a good idea because you might be getting into the
area where the battery is going to have a problem. This type of
charger typically adds a timer to control the amount of charge that's
put into the battery. Another way to prevent overheating to to
monitor the battery temperature. For example the charger for the
Ni-Cad BB-590 battery does not check the battery chemistry because when
a sealed Ni-Cad is charging the chemical reaction causes a temperature
rise that's not present with Ni-Cad batteries.
If DC current is used in an attempt to fast charge a battery, say at a
rates way above C/10 the battery will not charge and might vent,
explode, catch fire or some combination of these. NOT a good idea.
DC Voltage with a Current Limit
This is a common way to charge a Lead Acid battery. When the
battery is near dead it will draw current at the limit and as it
charges the terminal voltage goes up and so the current
decreases. At full charge only a trickle of current is flowing
into the battery. One problem is that the value of the voltage
depends on the battery temperature.
Pulse Methods
There are a number of methods where the charging current or voltage is
applied as a pulse or as pulses of different amplitudes. By
measuring the voltage with no load or with one or more different loads
some idea of the battery State Of Charge (SOC) can be determined and
this can be used to terminate the fast charge and switch to a trickle
to topping charge.
Burp Charging
A Burp Charger uses high current pulses for charging (maybe 10 C) and
also has high current (maybe 10 C) pulses discharging the battery
intermixed with the charging pulses. In order to work the energy
in the discharge pulses needs to be much much less than the energy in
the charging pulses. Wilford Burkett has a number of patents on
this method. As is common with patented ideas they don't show up
in reference text books. For example the 2"+ thick
"Handbook of Batteries" Third Edition, ISBN 0-07-135978-8 has no
mention of Burp or Pulse charging methods, yet the patent office has a
large number of patents on these topics.
My experience comparing the Maha C777+ charger that uses a pulse method
to measure the battery condition compared to the
Proper model BB-590
that uses the Galaxy 1702 smart Burp Charging controller chips
indicates that burp charging is a much better way to go. It does
a fast charge while only warming the battery, whereas the C777+ gets
the batteries very hot, and if the external temperature sensor is not
in good contact with a battery being charged these a good possibility
of damaging a battery by overheating it.
6 Dec 2007 - I think a Burp Trickle charger could be made that would
maintain Ni-MH or Ni-Cad battery packs, i.e. put back the power that
would otherwise be lost to self discharge. If this is of interest
let me know.
See the
Patents section below for more on Burp
Charging.
Charge
Termination
The standard method of charging a battery when it's known to be discharged is to charge at C/10 for 16 hours. The
Maha C9000
has a break-in mode (aka IEC capacity analysis) that: (1) 16 hr charge
@ C/10, (2) rest 1 hour, (3) discharge at C/5, (4) rest 1 hour, 16 hr
charge @ C/10. This is recommended for new batteries (which have
been sitting for many months and so are close to fully discharged) or
batteries that are known to be discharged. It gives the battery a
full capacity charge discharge cycle. Note that a battery that
was 100% efficient on the charge cycle would only need 10 hours at C/10
rate to charge. At 16 hours an extra 60% of it's capacity is
being fed to the battery.
C/10 and Time
When slow charging (C/10 is considered a slow charge) the battery will
not overheat and so there's no time limit. For most batteries 16
hours is enough to be sure you have fully charged the battery.
The
PP-7286/U uses this method.
There is a potential problem with this method when the ambient
temperature is hot in that a battery with a partial to full charge at
the start might over heat.
-dV/dT
As a Ni-Cad battery nears end of charge the voltage rises faster that
it did for most of the charge then peaks (the slope is zero) then falls
off with increasing negative slope. By looking for the negative
slope the charge can be terminated very close to the 100% of charge
point. This does not work for a C/10 charge but need some higher
rate.
A similar effect is present on Ni-MH cells but the size of the peak is
much smaller. So a charger made for Ni-Cads that uses -dV/dt
termination will not properly detect end of charge on a Ni-MH cell.
As of Dec 2007 both Sanyo and Duracell (the only ones I've checked
recently) do not recomend -dV/dt as a charge termination method for
Ni-MH.
Zero Slope
Similar to the -dV/dt method above but instead of looking for the negative slope it terminates at the peak.
Orthogonal Measurements
When making a measurement it's good to have Orthogonal
parameters. For example when measuring the capacity of a battery
the cell voltage is used to determine the end of discharge. A
plot of battery cell voltage will have a steep slope (be nearly at
right angles to the time axis).
But if zero slope is used the slope of the curve is parallel to the
time axis so it's very difficult to say when it's exactly zero.
|
This method can have problems with false termination due to noise or temperatue changes and so is not recomended.
Temperature
This is an absolute max temperature charge termination. When a
Ni-MH cell receives over charge at rates above C/10 it will get very
hot so a temperature sensor can be used to terminate the
charging. Tends to over charge when it's cold and undere charge
when it hot. This is not recommended as a normal charge
termination method, but is recommended as a safety back termination
method. the reason is that when any battery gets very hot the
life is shortened. For some applications where battery life is
not a concern like racing there is an advantage is getting the battery
hot because it produces more power.
dTemp
In delta Temperature the change in temperate is sensed. This has
an advantage in that the ambient temperature has less impact. If
absolute temperature is used and it's very hot then the charging may be
terminated too soon. In delta Temp the battery starts out at the
ambient temperature and charge is stopped when the battery temp
increases some specified amount. This can work for fast charges
where the charge time is fairly short, but has problems it the charge
time is many hours because the ambient temperature changes during the
night and day.
Duracell recommends this method when the parameters are matched to the
specific battery. For their "D" cell Ni-MH charged at 1C
terminate at delta T of 15 deg C (27F). No topping charge
needed. And use a 60C (140F) safety termination.
dTemp/dt
This is an improvement on the dTemp method since it's looking at the
slope and so will not be as influenced by the daily temperature ambient
temperature changes. Duracell has a plot of battery capacity vs.
the number of charges (1 to pver 300) comparing -dV/dt to
dTemp/dt. For the first 250 charge cycles the -dV/dt method
provides about 5% more capacity but after 250 cycles dTemp/dt provides
more capacity and the -dV/dt capacity starts falling off rapidly and
the battery is dead by cycle 350 but the dTemp/dt battery goes to
about 430 cycles.
Duracell recomends this method with a 1C charge rate and termination at
1 deg C/min (1.8 deg F/min) with a 60 deg C temperatue backup. To
make up for the 5% lower capacity this method prvides they also
recomend a top off charge of C/10 for a half hour (that equals C/20 or
5%).
Pressure
When a battery is charged not only does the temperature increase but
also the pressure inside increases. There are no commercial
chargers that I know of using the pressure increase.
Probably because it's not easy to measure.
Others
There are a large number of other patented methods of charge
termination. The burp methods for example. Or the battery
temp - ambient temp method.
Self Discharge
When any primary or secondary battery
is sitting on a shelf with no load attached it will discharge.
For the common Ni-Cad or Ni-MH chemistries this may amount to one or
more percent per day. For some data see my
Ready to Use Battery (low self discharge) web page.
In addition to discharging the battery also looses the ability to be
charged. This is a temporary effect, but all the chargers I've
seen don't know how to handle it. If you see that the capacity of
a battery is much lower than expected it's good to put in on a few
cycles of discharge and charge and note how the capacity is changing
cycle to cycle. If it does not improve the battery is dead.
But if it does improve keep cycling until it flattens out.
Trickle or Float
A lead acid battery can have a constant
voltage applied that's near the fully charged battery voltage and
typically can only supply small currents. If the cell voltage
decreases due to self discharge then current flows and keeps the
battery fully charged. This is very good for backup batteries and
for maintaining a battery in a parked car.
Ni-Cad and Ni-MH batteries have a self discharge rate of about C/300 to
C/500 (that's 0.3 to 0.2 %/hour). But these chemistries do not
accept a DC charge at this low a rate according to Sanyo.
Duracell does recommend a C/300 trickle charge to maintain it's Ni-MH
cells.
Note if the hourly self discharge rate is C/400 that's 0.0025C per
hour. Since the discharge depends on the current capacity it
decreases and the capacity decreases. To get the daily rate use
(1-C/400)^24 so for C/400 the capacity after 24 hours is 0.94 or the
battery has lost 5.8% of it's capacity. This is an exponential
type discharge not linear. Also it's very temperature dependent,
the hotter the faster the self discharge.
The self discharge is improved when a battery is stored in a cold
location. But the capacity of a battery like Ni-MH or Ni-Cad
decreases at cold temperatures and decreases rapidly for temperatures
near water freezing.
Smart Batteries
Li-Ion and Li-polymer batteries have a
venting & catching fire type problem if their terminal voltage gets above
or below specified limits or if the current exceeds a specified limit
(either charge or discharge). To prevent this each cell has a
safety circuit and the pack has a current monitor. If any of the
prohibited conditions exist a FET switch opens the terminals.
These protection circuits are digital in nature and can be connected to
a smart chip that can communicate using a one wire serial protocol with
the host load or charger. The chips also have coulomb counting
and can predict the battery discharge time (gas gauge).
Some of these use stock chips and public data protocols and can be used
in other applications. Others use a micro controller with a
proprietary interface protocol and can not be used by anyone
else. So that great eBay deal for a laptop battery that's for a
computer you don't have may be next to useless as far as the gas gauge is concerned.
Rechargeable Chemistries
A primary battery has a chemistry that
only goes in one direction (discharge). If you try and put charge
into this type of battery it's not going to charge and may very well do
something nasty. A lot of thought and effort goes into preventing
attempts at charging primary batteries. For example an early
BA-5800 (all military batteries with a name
starting BA- are primary types) used in a PLGR that was designed to
charge a battery when the
PLGR was connected
to a vehicle tended to explode the primary battery. The sockets
on the BA-5590 family of batteries are divided into two types primary
with 5 keying slots and secondary with 4 slots to mechanically prevent
a properly designed charging device from connecting to a primary
battery. The
BA-5590 primary battery
has no connection to pin 3, but all the secondary batteries in the
family connect negative pin 1 to pin 3. This way if a charger
uses pin 3 instead of pin 1 it can not charge a primary battery.
Lead Acid
This is one of the oldest types of
rechargeable battery and comes in a number of different forms.
I'm not going to spend much time on them except to say that you need to
keep them away from electronics. I got a very good deal on a
Gibbs precision oscillator because it was designed with the gel cell
batteries in the same box as the electronics. When during normal
charging the batteries vented with a track of sulfuric acid over time
the traces were etched from the PCBs in the warmer parts of the package.
Typically charged with constant voltage and current limit.
The Cyclon cylindrical Lead Acid deserves special mention. I learned about this battery when working with a military
O-1814
Rubidium Frequency and Time standard that uses them for a back up
battery. Virtually all the other batteries I've looked at
prohibit discharging to zero volts. For example if you discharge
a car battery to zero volts it's dead and will no longer take a
charge. BUT, the Cyclon can be discharged to zero with the
proviso that it will be charged within a reasonable short time, like
what would happen when there's a power failure.
When other types of batteries are used in backup systems the controller
needs to have a way of disconnecting the battery when the cell voltage
gets to the minimal allowed to prevent pulling the cell to zero volts.
It turns out that the designers of the O-1814 should have also done
that, since it was used in a vehicle mounted system , not an line
powered system where the battery would automatically get charged.
In the vehicle system if a soldier turns of the power to the whole
system at the central power panel then the O-1814 backup battery runs
to zero volts and does not get charged until the next time the system
is used which may be many months.
Alkaline
The Alkaline chemistry goes way back to
the
Leclanché Battery which could
be recharged by changing the electrolyte. The more modern
Alkaline battery has a chemistry that can go both ways, but has not
been optimized to do it efficiently. Rayovac does make a
rechargeable Alkaline battery but it has limited charge cycles when
compared to other rechargeable.
For many years Alkaline batteries used a small amount of Mercury to
prevent the zinc from oxidizing. When Mercury was removed from
Alkaline batteries there was a lot of development work (and many many
patents) on ways to replace it. If you look at a package of
Energizer or Wal-Mart Alkaline batteries you will see a couple dozen
patent numbers, and almost all of them are related to ways of getting
around the Mercury problem. But a couple of them are related to
getting more energy out of the battery, see:
6022639
Zinc anode for an electochemical cell Feb 8, 2000 429/229 (15.6 amp
short ckt curr ? batt size)
6589693
High discharge electrolytic manganese dioxide and an electrode and
alkaline cell incorporating the same
July 8, 2003 429/224; 429/218.1; 429/229; 429/231.8
These patents are aimed at providing high discharge currents and are a
big improvement over conventional Alkaline cells.
For more see my 5590BA web page on
internal
resistance and load testing.
Ni-Cad
This was the rechargeable battery that
enabled a very large number of battery powered devices like drills,
tooth brushes, electric shavers, hand held radios, etc. that needed a
battery that could supply high currents and was small and light
weight. There was a "memory" problem with early Ni-Cads, but it's
not clear to me if this is still true of modern Ni-Cads. Know for
their good performance under heavy discharge and heavy charge. A
workhorse battery.
Typically charged using a constant current. If above C/10 then a
charge termination methods is needed such as a timer, terminal voltage,
it's slope vs. time, or some pulse method is used.
Ni-MH
These provide more Amp Hours than a
Ni-Cad of the same size. They may not have the Ni-Cad memory
problem by may have a decrease in capacity after some amount of
use. This effect may also be caused by improper charging (i.e.
overheating during charge). For example a battery that should
have a run time of 6.9 hours only has a run time of 4.2 hours after a
single over charge incident.
These batteries get very hot when fast charged and they are near full
(maybe at 80% of capacity). If an over temperature method is used
to terminate charge either some capacity is sacrificed or there is a
danger of damaging the battery by over heating.
The peak voltage and voltage slope methods that work for a Ni-Cad will
not work for a Ni-MH unless they are much improved versions since the
voltage increase with the Ni-MH is smaller and harder to detect.
A charger that can charge a Ni-MH will typically also work with a
Ni-Cad, but not the other way around.
Li-Ion
These cylindrical cells offer the
highest Watt Hour capacity for the volume they occupy. This is
the current standard battery for laptop computers, cell phones and
other high tech products.
They require protection circuits and specialized chargers.
Li-Poly
These pouch cells offer the highest
Watt Hour capacity for the weight and are popular with RC model
airplane hobbyists. They have the same need for protection
circuits and special chargers as the Li-Ion batteries although the RC
airplane folks typically remove the protection so that they will not
crash the plane due to a low battery, but they may burn up the family
car as a result.
Chargers
Commercial
Single Cell Chargers - there are a huge
number of these some cheap DC type and maybe others are Burp types.
Rayovac
3in1
- 4 station "D" cell or smaller - will charge their rechargable
Alkaline as well as Ni-Cad and Ni-MH
Maha
H-C777Plus - single station combined charger discharger with LCD
readout of mAH put in to removed, uses mag mount thermoter. No
information on how it works, but appears to be a DC type with pulse for
state of charge measurement. Gets Ni-MH cells very hot on every
charge.
Lab Type Power Supply - can be used for charging all kinds of batteries
and will bring back from dead batteries that the Maha will not.
Battery Space
Universal Smart Charger -
Maha MH-C401FS - AAA/AA smart charger - supposed to do a good job on Ni-MH cells. Got it for Sanyo
Ready To Use (long shelf life) cells
Maha
MH-C9000 - this is a charger analyzer
for AA or AAA cells, but I don't see why it could not also work with C
or D cells, i.e. any single cell rechargable battery that was Ni-Cad or
Ni-MH.
Triton2 Charger Discharger Cycler
Military
706841-801
- 5 Station Magnavox for PRC-68 type Ni-Cad batteries with internal
thermistors DC fast & trickle
PP-7286/U -
5 station for a varity of
Ni-Cads uses digital circuitry and regulated current for specified time
then shutoff
PP-7601 - 6
station for PRC-68 type batteries digital circuitry, not manual or info.
PP-8444A/U -
2 or 4 station suitcase universal charger different versions can charge
different chemistries.
TMQ-34
Weather Station Charger DC low rate (100 ma) charger
Patents
Class
320 Electricity: Battery or Capacitor Charging or Discharging
127 Battery or Cell Discharging
128

With charging
129

Pulsed discharge (Burp)
137 Battery or Cell Charging
139 
Pulsed
152

Detection of current or
voltage amplitude
155

Time control
156

Detection of current or
voltage differential (e.g., slope, etc.)
160

Multi-rate charging (e.g.,
plural charge rates before a maintenance charge, etc.)
Burp Charge
There are those on the internet that think Burp Charge is snake oil and
does not work. Burp Charging does NOT cause the cells to get
hot. The Maha C777+ charger stops charging Ni-MH cells based on
an over temperature error (140 F). Burp Charge is a pulsed
discharge during the charging
process.
Wilford Burkett's Burp Charge Patents
3517293
Rapid Charging of Batteries June 23, 1970
320/129;
320/152
3559025
Rapid Charging of Batteries Jan 26, 1971
320/129;
320/153
3597673
Rapid Charging of Batteries Aug 3, 1971
320/129;
320/153
3609502
High Frequency Battery Charger Employing an Inverter Sep 28, 1971
320/129;
320/139; 320/158; 320/DIG17 - includes Burp
3609503
Termination of Rapid Charging of Batteries Sep 28, 1971
320/129;
320/152; 320/DIG17 - Termination for a Burp charger
3614582
Rapid Charging of Batteries Oct 19, 1971
320/129;
320/139; 320/149; 320/DIG17
3614583
Rapid Charging of Batteries Oct 19, 1971
320/129;
320/139; 320/152;
320/DIG17
3626270
Battery Charger for Single Cells Dec 7, 1971 - also Burp
4413221 Method and circuit for determining battery capacity, Fred
Benjamin, Robert H. Heil (Christie Electric Corp), Nov 1, 1983,
320/48; 320/14; 324/427; 324/435
Uses discharge pulses during charging. analog circuitry
4746852 Controller
for battery charger, Ray J. Martin (Christie Electric Corp), May 24, 1988, 320/20;
320/14;
320/21;
320/31;
320/39
uses the time deritive to determine when charged
References:
|
| 3597673 |
RAPID CHARGING OF
BATTERIES |
Wilford Burkett
|
Aug 1971 |
| 4006396 |
Universal battery charging
apparatus <>Burp
|
Motorola
|
Feb 1, 1977 |
| 4134056 |
Apparatus for charging
rechargeable battery <>Burp |
Sanyo |
Jan 9, 1979 |
| 4213081 |
Method and apparatus for
charging sealed Ni-Cad batt <>Burp Peak detection (Vnow < Vmax)
|
no company
|
Jul 15, 1980 |
| 4354148 |
Apparatus for charging
rechargeable battery <>Burp |
Sanyo |
Oct 12, 1982 |
| 4385269 |
Battery charger BURP
|
Redifon |
May 24, 1983 |
| 4388582 |
Apparatus and method for
charging batteries <>Burp delta
|
Black & Decker |
Jun 14, 1983 |
| 4503378 |
Charging system for
nickel-zinc batteries <>Burp inflection
|
GM
|
Mar 5, 1985 |
| 4639655 |
Method and apparatus for
battery charging <>Burp |
|
Jan 27, 1987 |
4829225 Rapid battery charger, discharger and conditioner
May 9, 1989
320/129
- More modern Burp charger
6459243 Multiple plateau battery charging method and system to
fully charge the first plateau
Oct 1, 2002 320/155; 320/160 - has an overview of other types of
charger patents.
3258671
Method for Increasing the Capacity of Silver Electrodes
(Silver-Cadmium, Silver-Zinc) -U.S. Navy Jun 28, 1966 320/139
4499415 Battery rapid charging circuit
Feb 12, 1985
320/139 ; 320/163
Links
Back to Brooke's Products
for Sale, Batteries, Rechargeable
Battery Summary For Kosovo Deployment -
Charger-on-the-Move
(COTM) PP-8481/U -
Battery
spreadsheet with cross links replacements and chargers -
Back to Brooke's PRC68, Contact, Alphabetical web page list, Battery Testers, Products
for Sale, Batteries, Military
Information, Personal Home
06533 hits since May 04 2007 page created April. 2005.